just my 2 cents worth. I also looked at
http://www.cisco.com/en/US/products/hw/switches/ps708/
prod_module_installation_guide09186a0080163594.html#wp60133
and quoted in there is " Important Note: You cannot have a DFC in a
system with a Supervisor Engine 720."
could be important
Paul
On Jan 13, 2005, at 8:32 AM, Arnold Nipper wrote:
On 13.01.2005 13:45 Marcel Lemmen wrote
The c6509 with Sup720 can handle 720Gbps of switching traffic in
total,
but what happens if I transfer 40Gbps from one slot to the other slot
with
4x10GE (since we have 8 10GE ports)? As far as I know the c6509 has a
8Gbps backplane and therfor you shouldn't be able to transfer more
then
8Gbps from one slot to another, or am I wrong in this one?
The buildt-in switching fabric can handle 40Gbps
Using dCEF it
would be possible to transfer 40Gbps of traffice within one slot but
not
between slots or not?
You are able to transfer 40Gbps of traffic between two slots as well
Have a look
http://www.cisco.com/en/US/products/hw/switches/ps708/
products_qanda_item09186a0080159963.shtml for more information