How about "atm scrambling cell-payload"
Dave
Voll, Scott wrote:
Loop back the alarm and cell go off but I have a green enable and
carrier.
-----Original Message-----
From: MADMAN [mailto:david.madland at qwest.com]
Sent: Thursday, January 20, 2005 1:05 PM
To: Dave Temkin
Cc: Voll, Scott; cisco-nsp at puck.nether.net
Subject: Re: [c-nsp] Trying to get an ATM ciruit up
You can also try looping the coax tx - rx. You may have to change
the timing to internal.
dave
Dave Temkin wrote:
Do you get the RXCLK light coming on?
If not, it's a physical cabling issue.
On Thu, 20 Jan 2005, Voll, Scott wrote:
Can anyone give me a hit as to what I'm doing wrong?
I'm trying to bring up an ATM DS3 and I'm getting Rx loss.
My config is below. Am I missing more configurations?
interface ATM4/0/0
no ip address
!
!
interface ATM4/0/0.33 point-to-point
description XXXXXX
ip address xxx.xxx.xxx.xxx 255.255.255.252
pvc 1/33
vbr-nrt 1024 1024
encapsulation aal5snap
This is a FR to ATM configuration using a CAT 6509 flexwan / ATM DS3
Card (enhanced).
Telco is pointing finger my way. Do I need to setup Controller in
global config?
TIA
"Emotion should reflect reason not guide it"